Line 24: | Line 24: | ||
* <p>Change the smart_center_backup parameter to true using dbedit, gui-dbedit or by editing the objects_5_0.C file. | * <p>Change the smart_center_backup parameter to true using dbedit, gui-dbedit or by editing the objects_5_0.C file. | ||
− | + | '''One the primary cma''' | |
# stop cma | # stop cma |
Revision as of 07:03, 21 May 2013
Problem description
- Management HA is failing to sync the secondary CMA via SmartDashboard > Policy > Management High Availability
- Error message: "Failed to receive current status. Reason: 'Management High Availability feature is not enabled.
- The smart_center_backup parameter in the objects_5_0.C is false when it should be true
[Expert@provider-1]# mdsenv cma-primary [Expert@provider-1]# cpmiquerybin attr "" network_objects "management='true'" -a __name__,smart_center_backup cma-primary true cma-secondary false
- The secondary CMA is newly created and has never been synchronized. Synchronization during the CMA creating failed.
- Error messages from cpca.elg of the secondary cma:
main: could not initiate the Certificate Authority. No Certificate Authority existing
- The cpca process on the secondary CMA is down and fails to start.
[Expert@provider-1]# mdsstat | +-----+----------------+-----------------+------------+----------+----------+----------+ | Type| Name | IP address | FWM | FWD | CPD | CPCA | +-----+----------------+-----------------+------------+----------+----------+----------+ | MDS | - | 171.178.7.1 | up 3421 | up 3420 | up 3419 | up 3956 | +-----+----------------+-----------------+------------+----------+----------+----------+ | CMA | cma-primary | 171.155.44.74 | up 21716 | up 21715 | up 21705 | down |
Solution
-
Change the smart_center_backup parameter to true using dbedit, gui-dbedit or by editing the objects_5_0.C file.
One the primary cma
- stop cma
- mdsenv cma-primary
- rm $FWDIR/conf/mgha/*
- start cma
- Manually synchronized the secondary via SmartDashboard > Policy > Management HighAvailability