Nokia firewall fails to boot off a RAID pair of drives moved from another chassis. This is because the volume is deactivated when moved between systems.
Errors: Boot manager loaded. Entering autoboot mode. Type any character to enter command mode. Error: /image on /dev/mirror/gmroots1f
does not exist or is not a file
umount: /mnt: not a file system root directory boot failed
Solution
activate raid volume
BOOTMGR[1]> raid -------------------------------------------------------- IPSO LSI Logic Configuration Utility version : Version 0.5, June 8, 2007 -------------------------------------------------------- Adapter Type ............. 3 (SAS Adapter) PCI Device ID ............ 0x0056 Hardware Revision ID ..... 0x0004 Devices in Volume ........ 0 FW Version ............... (01.18.00.00) decimal MPI Version of FW ........ MPI Version 1.5.13.0 -------------------------------------------------------- 1) Raid Options Sub-Menu 2) Firmware operations q) EXIT -------------------------------------------------------- Choose an option: 1 ------------------- RAID MENU -------------------------- 1) Show volume(s) 2) Show physical disk(s) 3) Get Volume Status
Options below available from boot manager ----------------------------------------- 10) Disable volume 11) Enable volume 12) Deactivate volume 13) Activate volume 30) Create RAID Volume 31) Delete RAID Volume q) Main Menu -------------------------------------------------------- Choose an option: 13 Volume: [0-1 or RETURN to quit] 0
Volume 0 is being activated
Changes made, doing a camcontrol rescan Re-scan of bus 0 was successful Re-scan of bus 0 was successful Waiting 5 seconds for SCSI devices to settle ...... done ------------------- RAID MENU -------------------------- 1) Show volume(s) 2) Show physical disk(s) 3) Get Volume Status
Options below available from boot manager ----------------------------------------- 10) Disable volume 11) Enable volume 12) Deactivate volume 13) Activate volume 30) Create RAID Volume 31) Delete RAID Volume q) Main Menu --------------------------------------------------------
Choose an option: 1 ------------------ Show Volumes ------------------------ 1 volume is active, 2 physical disks are active
Volume 0 is Bus 0 Target 0, Type IM (Integrated Mirroring) Volume State: degraded, enabled, resync in progress Volume Settings: write caching enabled, auto configure Volume draws from Hot Spare Pools: 0 Volume Size 76158 MB, Stripe Size 0 KB, 2 Members Primary is PhysDisk 0 (Bus 0 Target 4) Secondary is PhysDisk 1 (Bus 0 Target 1)
------------------- RAID MENU -------------------------- 1) Show volume(s) 2) Show physical disk(s) 3) Get Volume Status
Options below available from boot manager ----------------------------------------- 10) Disable volume 11) Enable volume 12) Deactivate volume 13) Activate volume 30) Create RAID Volume 31) Delete RAID Volume q) Main Menu -------------------------------------------------------- Choose an option: q -------------------------------------------------------- 1) Raid Options Sub-Menu 2) Firmware operations q) EXIT --------------------------------------------------------
Choose an option: q Re-scan of bus 0 was successful Re-scan of bus 0 was successful Waiting 5 seconds for SCSI devices to settle .. Type 'boot <enter>' to continue boot process ..
If the device O.S. is ipso 4.x, then you are done and it should be ready to boot. If ipso 6.x, continue...
relabel volume metadata (ipso 6.x)
check macbase data for mismatch