CMM Shelf Manager CLI Command Summary

From cpwiki.net
Jump to: navigation, search
Check Point Profressional Services
Shelf Manager CLI Command Summary

Command

Parameters

Description

activate

IPMB address

FRU device ID

Activates the specified FRU.

alarm

alarm type

Activates or clears Telco alarms.

board -v

slot number (optional)

Shows information about blade servers.

boardreset

slot number

Resets the specified ATCA blade server.

console

slot number

Opens a console session on the node blade server in the specified slot.

deactivate

IPMB address

FRU device ID

Deactivates the specified FRU.

exit|quit

 

Exits from the interpreter in interactive mode.

fans

IPMB address (optional)

FRU device ID (optional)

Shows information about fans.

fru

IPMB address (optional)

FRU device ID (optional)

FRU type (optional)

Shows information about one or a group of FRUs in the shelf; FRUs are selected by type or by the parent IPM controller.

frudata

IPMB address (optional)

FRU device ID (optional)

block/byte offset (optional)

data (optional)

Provides raw access to the FRU. Information on the specified FRU.

frudatar

IPMB address

FRU device ID

File name

Reads the FRU data area of the specified FRU and stores the data in the specified file.

frudataw

IPMB address

FRU device ID

File name

Writes the FRU data in the specified file into the FRU data area of the specified FRU.

fruinfo -v

IPMB address

FRU device ID

Provides user-friendly FRU Information output.

getthreshold | threshold

IPMB address (optional)

sensor name (optional)

sensor number (optional)

Shows threshold information about a specific sensor.

help

 

Shows the list of supported commands.

ipmc

IPMB address (optional)

Shows information about one or all IPM controllers in the shelf.

minfanlevel

fan level (optional)

Shows or sets the minimum fan level.

ps -ef |grep hp

 

Checks the openhpi status.

sensor

IPMB address (optional)

sensor name (optional)

sensor number (optional)

Shows information about one or a group of sensors; sensors are selected by IPM controller address, number or name.

sensordata

IPMB address (optional)

sensor name (optional)

sensor number (optional)

Shows value information for a specific sensor.

sensorread

IPMB address

sensor number

Shows raw value information for a specific sensor (ignoring any Sensor Data Record describing the sensor).

setfanlevel

IPMB address

FRU device ID

level

Sets a new level for the fan controlled by the specified FRU.

Use clia setfanlevel 20 3 5 to get the fans to slow down.

setfanpolicy

IPMB address

FRU device ID

action to be taken: ENABLE or DISABLE

timeout (optional)

site type (optional)

site number (optional)

Enables or disables fan trays for cooling management in addition to the Fan Geography record if this one is presented in the Shelf FRU.

setthreshold

IPMB address

sensor name

sensor number

threshold type

threshold value

Changes a specific threshold value (upper/lower, critical/non-critical/non-recoverable) for a specific sensor.

setuserlabel

shelf name

slot number name

Configures user assigned names for the shelf and the blade servers. Blade server names are assigned to slot numbers.

shelf

subcommand, with its parameters

Shows general information about the shelf; several subcommands allow setting shelf attributes and getting additional information about specific areas.

shelfaddress

Shelf Address string (optional)

Gets or sets the Shelf Address field of the Address Table within Shelf FRU Information.

shelf address_table

 

Shows the address table record in the shelf FRU info with shelf address and list of address table entries. For each entry, shows hardware address, site type, and site number.

shelf cooling_state

 

Shows the current cooling state of the shelf with normal, minor, major, and critical alert information.

shelf fans_state

 

Shows the current state of the fan techometers in the shelf with normal, minor, major and critical alert information.

shmstatus

 

Shows the Shelf Manager Active/Backup status.

showhost

slot-number

Displays version information about the firmware on certain Netra CP3x60 node blade servers.

showunhealthy

 

Shows the unhealthy components of the shelf.

switchover

 

Initiates a switchover to the backup Shelf Manager.

terminate

 

Terminates the Shelf Manager without rebooting the shelf management card.

version

 