Below is a console/terminal log of a new hard drive being installed, replacing a failed drive, and being added back to the raid mirror.
BOOTMGR[4]> sysinfo
CPU 0: 2660 MHz Intel(R) Xeon(R) CPU E5430 @ 2.66GHz Memory: 2663497728 (2048M bytes) Disk Devices: IO port 0x1f0 adc0: unit 0 (ad0): <STEC M2+ CF 9.0.2> 128MB (250880 sectors), 980 cyls, 8 heads, 32 S/T SCSI-DISK-A (da0): <ATA FUJITSU MHY2080B 010C> 80026MB (156301488 sectors), 9729 cyls, 255 heads, 63 S/T, 512 B/S SCSI-DISK-B (da1): <ATA FUJITSU MHY2080B 010C> 80026MB (156301488 sectors), 9729 cyls, 255 heads, 63 S/T, 512 B/S Network Interfaces: eth-s4p1: flags=130<BROADCAST,MULTICAST,PRESENT> ether 00:a0:8e:c0:c2:f4 half duplex eth-s4p2: flags=130<BROADCAST,MULTICAST,PRESENT> ether 00:a0:8e:c0:c2:f5 half duplex eth-s4p3: flags=130<BROADCAST,MULTICAST,PRESENT> ether 00:a0:8e:c0:c2:f6 half duplex eth-s4p4: flags=130<BROADCAST,MULTICAST,PRESENT> ether 00:a0:8e:c0:c2:f7 half duplex loop0: flags=10b<UP,LINK,LOOPBACK,PRESENT> tun0: flags=107<UP,LINK,POINTOPOINT,PRESENT> BOOTMGR[5]> raid
======================================================== IPSO LSI Logic Configuration Utility version : Version 0.5, June 8, 2007 ======================================================== Adapter Type ............. 3 (SAS Adapter) PCI Device ID ............ 0x0056 Hardware Revision ID ..... 0x0004 Devices in Volume ........ 0 FW Version ............... (01.18.00.00) decimal MPI Version of FW ........ MPI Version 1.5.13.0 ======================================================== 1) Raid Options Sub-Menu 2) Firmware operations q) EXIT ========================================================
Choose an option: 1
=================== RAID MENU ========================== 1) Show volume(s) 2) Show physical disk(s) 3) Get Volume Status
Options below available from boot manager ----------------------------------------- 10) Disable volume 11) Enable volume 12) Deactivate volume 13) Activate volume 30) Create RAID Volume 31) Delete RAID Volume q) Main Menu ========================================================
Choose an option: 30 B___T___L Type Serial Product Rev Blocks Disk MB 1. 0 0 0 Disk K449T8825xxx FUJITSU MHY2080B 010C 156301488 76319 2. 0 1 0 Disk K449T8625yyy FUJITSU MHY2080B 010C 156301488 76319
To create a volume, select two or more of the available targets The first selection will be Migrated as MASTER, keeping the data
Select the primary drive : [1-2 or RETURN to quit] 1 Select a secondary drive : [1-2 or RETURN to quit] 2
2 physical disks were created
Setting volume type: [0=Mirroring] Setting volume size: 76158 MB Enabled write caching by default.
Volume was created
Changes made, doing a camcontrol rescan Re-scan of bus 0 was successful Re-scan of bus 0 was successful Waiting 5 seconds for SCSI devices to settle ...... done
=================== RAID MENU ========================== 1) Show volume(s) 2) Show physical disk(s) 3) Get Volume Status
Options below available from boot manager ----------------------------------------- 10) Disable volume 11) Enable volume 12) Deactivate volume 13) Activate volume 30) Create RAID Volume 31) Delete RAID Volume q) Main Menu ========================================================
Choose an option: 1 ------------------ Show Volumes ------------------------ 1 volume is active, 2 physical disks are active
Volume 0 is Bus 0 Target 0, Type IM (Integrated Mirroring) Volume State: degraded, enabled, resync in progress Volume Settings: write caching enabled, auto configure Volume Size 76158 MB, Stripe Size 0 KB, 2 Members Primary is PhysDisk 0 (Bus 0 Target 4) Secondary is PhysDisk 1 (Bus 0 Target 1)
=================== RAID MENU ========================== 1) Show volume(s) 2) Show physical disk(s) 3) Get Volume Status
Options below available from boot manager ----------------------------------------- 10) Disable volume 11) Enable volume 12) Deactivate volume 13) Activate volume 30) Create RAID Volume 31) Delete RAID Volume q) Main Menu ========================================================
Choose an option: q ======================================================== 1) Raid Options Sub-Menu 2) Firmware operations q) EXIT ========================================================
Choose an option: q Re-scan of bus 0 was successful Re-scan of bus 0 was successful Waiting 5 seconds for SCSI devices to settle .. Type 'boot <enter>' to continue boot process ..
BOOTMGR[13]> sysinfo CPU 0: 2660 MHz Intel(R) Xeon(R) CPU E5430 @ 2.66GHz Memory: 2663497728 (2048M bytes) Disk Devices: IO port 0x1f0 adc0: unit 0 (ad0): <STEC M2+ CF 9.0.2> 128MB (250880 sectors), 980 cyls, 8 heads, 32 S/T DISK-A-B Volume (da0): <LSILOGIC Logical Volume 3000> 79857MB (155971584 sectors), 9708 cyls, 255 heads, 63 S/T, 512 B/S Network Interfaces: eth-s4p1: flags=130<BROADCAST,MULTICAST,PRESENT> ether 00:a0:8e:c0:c2:f4 half duplex eth-s4p2: flags=130<BROADCAST,MULTICAST,PRESENT> ether 00:a0:8e:c0:c2:f5 half duplex eth-s4p3: flags=130<BROADCAST,MULTICAST,PRESENT> ether 00:a0:8e:c0:c2:f6 half duplex eth-s4p4: flags=130<BROADCAST,MULTICAST,PRESENT> ether 00:a0:8e:c0:c2:f7 half duplex loop0: flags=10b<UP,LINK,LOOPBACK,PRESENT> tun0: flags=107<UP,LINK,POINTOPOINT,PRESENT>