Difference between revisions of "Adding drives to nokia firewall"

From cpwiki.net
Jump to: navigation, search
Check Point Profressional Services
(Created page with "Below is a console/terminal log of a new hard drive being installed, replacing a failed drive, and being added back to the raid mirror. BOOTMGR[4]> sysinfo CPU 0: 2660 MHz...")
 

Latest revision as of 22:09, 25 February 2013

Below is a console/terminal log of a new hard drive being installed, replacing a failed drive, and being added back to the raid mirror.


BOOTMGR[4]> sysinfo

CPU 0: 2660 MHz Intel(R) Xeon(R) CPU E5430 @ 2.66GHz
Memory: 2663497728 (2048M bytes)
Disk Devices:
       IO port 0x1f0 adc0: unit 0 (ad0): <STEC M2+ CF 9.0.2>
               128MB (250880 sectors), 980 cyls, 8 heads, 32 S/T
       SCSI-DISK-A (da0): <ATA FUJITSU MHY2080B 010C>
               80026MB (156301488 sectors), 9729 cyls, 255 heads, 63 S/T, 512 B/S
       SCSI-DISK-B (da1): <ATA FUJITSU MHY2080B 010C>
               80026MB (156301488 sectors), 9729 cyls, 255 heads, 63 S/T, 512 B/S
Network Interfaces:
eth-s4p1:  flags=130<BROADCAST,MULTICAST,PRESENT>
       ether 00:a0:8e:c0:c2:f4 half duplex
eth-s4p2:  flags=130<BROADCAST,MULTICAST,PRESENT>
       ether 00:a0:8e:c0:c2:f5 half duplex
eth-s4p3:  flags=130<BROADCAST,MULTICAST,PRESENT>
       ether 00:a0:8e:c0:c2:f6 half duplex
eth-s4p4:  flags=130<BROADCAST,MULTICAST,PRESENT>
       ether 00:a0:8e:c0:c2:f7 half duplex
loop0:  flags=10b<UP,LINK,LOOPBACK,PRESENT>
tun0:  flags=107<UP,LINK,POINTOPOINT,PRESENT>
BOOTMGR[5]> raid
========================================================
 IPSO LSI Logic Configuration Utility
 version : Version 0.5, June 8, 2007
========================================================
 Adapter Type ............. 3 (SAS Adapter)
 PCI Device ID ............ 0x0056
 Hardware Revision ID ..... 0x0004
 Devices in Volume ........ 0
 FW Version ............... (01.18.00.00) decimal
 MPI Version of FW ........ MPI Version 1.5.13.0
========================================================
1) Raid Options Sub-Menu
2) Firmware operations
q) EXIT
========================================================
Choose an option: 1
=================== RAID MENU ==========================
1)  Show volume(s)
2)  Show physical disk(s)
3)  Get Volume Status
Options below available from boot manager
-----------------------------------------
10) Disable volume
11) Enable volume
12) Deactivate volume
13) Activate volume
30) Create RAID Volume
31) Delete RAID Volume
q)  Main Menu
========================================================
Choose an option: 30
    B___T___L  Type    Serial        Product        Rev     Blocks  Disk MB
1.  0   0   0  Disk  K449T8825xxx FUJITSU MHY2080B 010C   156301488    76319
2.  0   1   0  Disk  K449T8625yyy FUJITSU MHY2080B 010C   156301488    76319
To create a volume, select two or more of the available targets
The first selection will be Migrated as MASTER, keeping the data
Select the primary drive :  [1-2 or RETURN to quit] 1
Select a secondary drive :  [1-2 or RETURN to quit] 2
2 physical disks were created
Setting volume type:  [0=Mirroring] 
Setting volume size:  76158 MB
Enabled write caching by default.
Volume was created
Changes made, doing a camcontrol rescan
Re-scan of bus 0 was successful
Re-scan of bus 0 was successful
Waiting 5 seconds for SCSI devices to settle ...... done
=================== RAID MENU ==========================
1)  Show volume(s)
2)  Show physical disk(s)
3)  Get Volume Status
Options below available from boot manager
-----------------------------------------
10) Disable volume
11) Enable volume
12) Deactivate volume
13) Activate volume
30) Create RAID Volume
31) Delete RAID Volume
q)  Main Menu
========================================================
Choose an option: 1
------------------ Show Volumes ------------------------
1 volume is active, 2 physical disks are active
Volume 0 is Bus 0 Target 0, Type IM (Integrated Mirroring)
 Volume State:  degraded, enabled, resync in progress
 Volume Settings:  write caching enabled, auto configure
 Volume Size 76158 MB, Stripe Size 0 KB, 2 Members
 Primary is PhysDisk 0 (Bus 0 Target 4)
 Secondary is PhysDisk 1 (Bus 0 Target 1)
=================== RAID MENU ==========================
1)  Show volume(s)
2)  Show physical disk(s)
3)  Get Volume Status
Options below available from boot manager
-----------------------------------------
10) Disable volume
11) Enable volume
12) Deactivate volume
13) Activate volume
30) Create RAID Volume
31) Delete RAID Volume
q)  Main Menu
========================================================
Choose an option: q
========================================================
1) Raid Options Sub-Menu
2) Firmware operations
q) EXIT
========================================================
Choose an option: q
Re-scan of bus 0 was successful
Re-scan of bus 0 was successful
Waiting 5 seconds for SCSI devices to settle ..
Type 'boot <enter>' to continue boot process ..


BOOTMGR[13]> sysinfo
CPU 0: 2660 MHz Intel(R) Xeon(R) CPU E5430 @ 2.66GHz
Memory: 2663497728 (2048M bytes)
Disk Devices:
       IO port 0x1f0 adc0: unit 0 (ad0): <STEC M2+ CF 9.0.2>
               128MB (250880 sectors), 980 cyls, 8 heads, 32 S/T
       DISK-A-B Volume (da0): <LSILOGIC Logical Volume 3000>
               79857MB (155971584 sectors), 9708 cyls, 255 heads, 63 S/T, 512 B/S
Network Interfaces:
eth-s4p1:  flags=130<BROADCAST,MULTICAST,PRESENT>
       ether 00:a0:8e:c0:c2:f4 half duplex
eth-s4p2:  flags=130<BROADCAST,MULTICAST,PRESENT>
       ether 00:a0:8e:c0:c2:f5 half duplex
eth-s4p3:  flags=130<BROADCAST,MULTICAST,PRESENT>
       ether 00:a0:8e:c0:c2:f6 half duplex
eth-s4p4:  flags=130<BROADCAST,MULTICAST,PRESENT>
       ether 00:a0:8e:c0:c2:f7 half duplex
loop0:  flags=10b<UP,LINK,LOOPBACK,PRESENT>
tun0:  flags=107<UP,LINK,POINTOPOINT,PRESENT>